201-Memory Error
Audible Beeps: None
Possible Cause: Memory failure detected.
Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 80
) and
replace failed components as indicated.
203-Memory Address Error
Audible Beeps: None
Possible Cause: Memory failure detected.
Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 80
) and
replace failed components as indicated.
207-Memory Configuration Warning - DIMM In Socket x does not
have Primary Width of 4 and only supports standard ECC
Advanced ECC does not function when mixing DIMMs with Primary Widths of x4 and x8.
Audible Beeps: 1 long, 1 short, or none
Possible Cause: Installed DIMMs have a primary width of x8.
Action: Install DIMMs that have a primary width of x4 if Advanced ECC
memory support is required.
207-Invalid Memory Configuration - DIMMs Must be Installed
Sequentially
Audible Beeps: 1 long, 1 short
Possible Cause: Installed DIMMs are not sequentially ordered.
Action: Reinstall DIMMs in proper order.